etekcity lasergrip 1022 manual

posted in: Uncategorised | 0

Point the Lasergrip towards the surface of measurement. This thermometer cannot test the temperature of target objects through across the glass. This creates a spot measurement area of 1.18 inches (3 cm) in diameter. inimo WIN NOTE: The Lasergrip LCD will display 'OH' when the measured temperature is above the measurable range, and will display 'OL' when the measured temperature is below the measurable range. Report any errors on this page in the comment box below. 1x Etekcity Lasergrip 1022 Thermometer 1x 9V DC Battery 1x User's Manual Note: 1. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air. Don't blindly guess where you're pointing your Infrared Thermometer, Added Function: The LCD screen is backlit, also has an Auto-Off function to extend the battery life, and features a low battery indicator so you never accidentally run out of juice (battery included), Note: Temperature readings from this devices are inanimate objects. Once the battery is properly installed, press the measurement trigger to activate the device. 1. Besides, the steam, dust, smog will lower the accuracy of testing. With a temperature measurement range that surpasses boiling points, the possibilities are endless. Etekcity stands behind the quality of every product sold and delivered by our team, hoping that each and every customer expectation is met and exceeded. • DO NOT expose the thermometer to direct sources of heat for extended periods of time. Copyright © 2011-2020 Manual-Hub.com - All Rights Reserved. Wood 0.90-0.95 Textile powdered 0.96 Paper 0.95 PAIR Polarity facing upward Charcoal Carbon 0.85 Sand 0.90 0.92-0.96 To take accurate temperature measurement of reflective surfaces with low emissivity, place a strip of black masking tape over the surface and allow for it to adjust to the temperature of the surface for approximately 30 minutes. Besides, the steam, dust, smog will lower the accuracy of testing. Please contact us Mon-Fri 9:00 AM - 6:00 PM PST at (855) 686-3835 or email support@etekcity.com visit etekcity.com for more products. Please contact us Mon-Fri 9:00 AM - 6:00 PM PST at (855) 686-3835 or email support@etekcity.com Safety Use & Care • DO NOT point the laser-light at another person or animal. Safely measure extreme temperatures ranging from -58°F (-50°C) to 1022°F (550°C) without ever needing to come in contact. 1x Etekcity Lasergrip 1022D Thermometer . Products names, logos, brands and other trademarks are the property of their respective trademark holders in the USA and other countries. Please Wait " + counter.toString() + " seconds. Post was not sent - check your email addresses! Gold 0.85-0.95 Dbtaneet put = 121 Iron 0.01-0. Versatile Design: Infrared Technology makes this thermometer handy to use when cooking and barbequing, performing auto maintenance, doing home repairs, and a host of other tasks; Measure all the from 58℉~1022℉/ -50℃~550℃ Connect a new DC 9V battery, making sure it's under the correct polarity. Doing so will void any warranty. THE LASER LIGHT IS INVISIBLE TO THE HUMAN EYE. 95 Steel and iron 0.80 Limestone 0.98 Wool Natural 10.94 Oxidized 0.5 Paint 0.93 Lead For the most accurate results, make sure the target has a surface area of twice the corresponding spot diameter. 0.80-0.90 Mortar 0.95 Brick DETEKCITY Asphalt 9V 6F22 or 6LR61 Battery 0.90-0.96 Rock 0.7 Marble Wiring is not bulging out of the compartment 0.94 0.90 a simpler life starts here. To make better accuracy, cover the surface to be measured with masking tape or flat black paint. 2. 2. NOTE 1. "; } }, 1000); }; var clickbtn = document.getElementById("btn"); clickbtn.onclick = startDownload; PDF Content Summary: Accordion Fold ETEKCITY Thank you for purchasing the Lasergrip 1022 Infrared Thermometer by Etekcity. Insert the battery into the compartment and close the compartment lid, making sure the wiring is not being pinched by the compartment lid. 1x Etekcity Lasergrip 1022D Thermometer 1x 9V DC Battery 1x User's Manual Note: 1. 4. Plaster 0.89-0.91 Emissivity The emissivity of a material is its efficiency in emitting thermal energy. D Material Emissivity Of Articles Feature Emissivity Material Oxidized 0.3 Human skin Polished 0.02-0.04 Graphite Feature Emlselvity INFRARED THERMOMETER (-'F-1022*F/4-60*c-350 THIS PUTOVA1914*W6T. Reliable Product This is a big seller in Amazon and many respected institution like Car Magazines, Airports, Universities purchase this product from us! Note: 1. Questions or Concerns? • Avoid direct/indirect eye contact with the laser-beam. Inaccurate results may occur when measuring reflective surfaces such as glass, polished wood, and granite. Please Wait 10 seconds. 1x Etekcity Lasergrip 1022 Thermometer 1x 9V DC Battery 1x User’s Manual . transparent 0.95 Brass Polished 0.02-0.05 Rubber 0.95 The device warning and aperture safety information are also labeled directly on the device; the sticker is located on the right side of the Lasergrip. Press the measurement trigger once again to make another measurement. This Etekcity non-contact IR temperature gun is easy to operate. USE EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. Measure the surface, scanning the taped section, eliminating the issue of inaccuracy. This thermometer cannot test the temperature of target objects through across the glass. These documentations are only intended for qualified technicians who are aware of the respective safety regulations. Ceramics O. • DO NOT allow children to operate the device • Use a 9V battery when replacing the battery within the device. In addition, the readout display features a backlight which can be turned on if needed. 2. The measured temperature for humans or animals will not be correct. The site uses cookies. All files are original, not repacked or modified in any way by us. There’s no waiting or setup required. 2. At Etekcity, we are proud to offer 24 hour order processing (excluding weekends and holidays). To make better accuracy, cover the surface to be measured with masking tape or flat black paint. Emissivity Adjustment / Max Temperatures 6. Laser On Back-light On Continue Scanning 5. Besides, the steam, dust, smog will lower the accuracy of testing. HOLD for continuous temperature reading RELEASE to lock the temperature result THIS PRODUCT COMPLIES WITH 21 CFR 1040.10 and 1040.11. User Manual Questions or Concerns? Besides, the steam, dust, smog will lower the accuracy of testing. • ALWAYS remove the batteries when cleaning the device. AVOID EXPOSURE EHS TRXX LASER RADIATION IS EMITTED FROM THIS APERATURE LASER RADIATION -- DO NOT STARE INTO BEAM WAVELENGTH 630-670nm MAXIMUM OUTPUT<1mW CLASS II LASER PRODUCT Operation Surface Temperature Measurement NOTE: The Lasergrip cannot measure the temperature of objects behind glass. By continuing to browse the site you are agreeing to our use of cookies. Features & Specifications • Laser guided targeting for aiming precision • Narrow distance-spot ratio for accurate results at greater distances • Safely measure hazardous or inaccessible objects • Standard 9V battery powers up to 12 hours of cumulative use • Auto-off after 15 seconds of inactivity • Measurement Range: -58°F ~1022°F (-50°C ~ 550°C) • Accuracy: + 2% / + 2°C • Resolution: 0.1°F/°C • Maximum Output: <1mW • Wavelength: 630 - 670nm • Distance-Spot Ratio: 12:1 • Response Time: <500ms • Emissivity (Adjustable): 0.1 - 1.0 • Battery: DC 9V IMPORTANT: Read all the instructions in this manual. WARNING: THIS DEVICE PRODUCES CLASS 2 LASER RADIATION. Max Temperature / Emissivity Result 8. Versatile Design: Infrared Technology makes this thermometer handy to use when cooking and barbequing, performing auto maintenance, doing home repairs, and a host of other tasks; Measure all the from 58℉~1022℉/ -50℃~550℃, Better Accuracy: The Distance to Spot Ratio is 12:1, meaning the Lasergrip 1080 can accurately measure targets at greater distances compared to most other IR Thermometers, Target Quicker: A built in Laser gives you the precision to hone in on the exact space you want to measure. 0.95 Oil 0.94 FCC Declaration This device complies with Part 15 of the FCC Rules. 2. DO NOT DISASSEMBLE THE DEVICE. The recommended distance to hold the Lasergrip from the surface of measurement is 14.17in (36 cm). Immediately replace the battery when the icon appears. This easy-to-use device lets you conveniently and accurately measure surface temperatures from a distance without the need of any direct contact.

Bangalore To Kerala Distance, High School Softball Bat Rules 2020, Wolfram Physics Criticism, Watzmann Mountain Hike, Aman Name Meaning In Punjabi, Dark Souls 3 Fps Ps4, 3 Ingredient Chocolate Oatmeal Cake, Titian Pesaro Altarpiece, Worksheet Of Interjection For Class 4,